. LD600-12 Operating Manual Serial No _____________________________ Purchase Date ______________ Note - Your warranty can o
LD600-12 Manual Selectronic Australia 8 LED (2) AC Overload should normally remain OFF. If the inverter shuts down due to too much AC load being dr
LD600-12 Manual Selectronic Australia 9 Demand Start Adjust LED (5) (green) ON It is sometimes necessary to adjust the demand start sensitivity to ov
LD600-12 Manual Selectronic Australia 10 Low Volts Adjust LED (5) (green) FLASHING To avoid total discharging of your battery the LD600-12 shuts down
LD600-12 Manual Selectronic Australia 11 Maintenance Inverter Periodic maintenance of your LD600-12 inverter involves little more than checking
LD600-12 Manual Selectronic Australia 12 3. Once a fortnight or as directed in your battery manufacturer, check the specific gravity (SG) of each b
LD600-12 Manual Selectronic Australia 13 Radio Frequency Interference Radio Frequency Interference (RFI) can be a problem for owners of inverters. RF
LD600-12 Manual Selectronic Australia 14 Fault Finding No indicators ON when power is first applied When first connected, if the LD600-12 shows
LD600-12 Manual Selectronic Australia 15 Product Warranty and Conditions These warranty conditions apply to the LD range of Inverters for sales withi
LD600-12 Manual Selectronic Australia 16 LD600-12 Specifications Inverter Type Microprocessor control circuit with PWM full bridge power stage. True
LD600-12 Manual Selectronic Australia 17 Miscellaneous Specifications Reverse Polarity Protection Output Voltage Accuracy 0-350 watts Output Freque
LD600-12 Volt Owners Manual Contents Page No. Introduction 1 Warranty Card 1 Installation 1 Batteries and Connections 4 Getting Started Quickly 6 Par
Selectronic Authorised Service Network Selectronic Australia Suite 5, 20 Fletcher Road Mooroolbark Victoria 3138 Australia Ph: +61 3 9727 66
LD600-12 Manual Selectronic Australia 1 Introduction Thank you for choosing to purchase the Selectronic LD600-12 TRUE SINE WAVE inverter. Many hours
LD600-12 Manual Selectronic Australia 2 Large amounts of DC current can be drawn by your LD600-12, care must be taken. Fixed Installation All fixed
LD600-12 Manual Selectronic Australia 3 Portable Use By using optional battery clips, the LD600-12 can be connected directly to a vehicle battery. Wh
LD600-12 Manual Selectronic Australia 4 Batteries and Connections Batteries are the key to maximum performance from your LD600-12, if a battery is to
LD600-12 Manual Selectronic Australia 5 Where batteries are joined in parallel, add the capacities together, the voltage will remain the same as each
LD600-12 Manual Selectronic Australia 6 Getting Started Quickly If you want to get powered up quickly here are the 11 simple steps. 1. Familiarise
LD600-12 Manual Selectronic Australia 7 Operation Five LEDs are provided on the front panel to indicate a number of parameters, and allow